smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-87-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue Serial ATA
Device Model: WDC WD5000BEVT-22ZAT0
Serial Number: WD-WX90AC947440
LU WWN Device Id: 5 0014ee 203ebec7b
Firmware Version: 01.01A01
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Mon Oct 30 12:50:30 2017 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 121) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: (13560) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 158) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 439
3 Spin_Up_Time 0x0027 186 179 021 Pre-fail Always - 1700
4 Start_Stop_Count 0x0032 095 095 000 Old_age Always - 5573
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
9 Power_On_Hours 0x0032 065 065 000 Old_age Always - 25604
10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 096 096 000 Old_age Always - 4681
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 242
193 Load_Cycle_Count 0x0032 161 161 000 Old_age Always - 118918
194 Temperature_Celsius 0x0022 114 090 000 Old_age Always - 33
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline - 0
SMART Error Log Version: 1
Warning: ATA error count 15928 inconsistent with error log pointer 1
ATA Error Count: 15928 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 15928 occurred at disk power-on lifetime: 4745 hours (197 days 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 61 46 00 4f c2 e0 Device Fault; Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
ef 03 46 00 4f c2 00 00 08:24:12.803 SET FEATURES [Set transfer mode]
b0 d2 f1 00 4f c2 00 00 08:24:12.803 SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE
b0 d8 00 00 4f c2 00 00 08:24:12.435 SMART ENABLE OPERATIONS
ec 00 00 00 00 00 00 00 08:24:12.367 IDENTIFY DEVICE
08 00 00 00 00 00 00 00 08:24:12.355 DEVICE RESET
Error 15927 occurred at disk power-on lifetime: 4745 hours (197 days 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 61 01 00 00 00 40 Device Fault; Error: ABRT at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 01 00 00 00 00 00 08:24:00.877 READ VERIFY SECTOR(S)
ef 10 02 00 00 00 00 00 08:23:59.880 SET FEATURES [Enable SATA feature]
ef 03 46 00 00 00 00 00 08:23:58.883 SET FEATURES [Set transfer mode]
c6 00 10 00 00 00 00 00 08:23:57.888 SET MULTIPLE MODE
ec 00 00 00 00 00 00 00 08:23:57.885 IDENTIFY DEVICE
Error 15926 occurred at disk power-on lifetime: 4745 hours (197 days 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 61 02 00 00 00 40 Device Fault; Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
ef 10 02 00 00 00 00 00 08:23:59.880 SET FEATURES [Enable SATA feature]
ef 03 46 00 00 00 00 00 08:23:58.883 SET FEATURES [Set transfer mode]
c6 00 10 00 00 00 00 00 08:23:57.888 SET MULTIPLE MODE
ec 00 00 00 00 00 00 00 08:23:57.885 IDENTIFY DEVICE
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed: read failure 90% 25082 12515935
# 2 Extended offline Completed: read failure 90% 25079 12515935
# 3 Short offline Completed without error 00% 2 -
# 4 Short offline Completed without error 00% 2 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.